    Structured Review

    Eppendorf AG microneedle array sensor
    Fabrication and characterization of the SiNW-FET-based <t>microneedle</t> array sensor. (a) Schematic illustration of the top-down fabrication process. (b) SEM images of the fabricated needles; the needles are 150 μm in width and ca. 250 μm in thickness (scale bar: 125 μm). The green inset shows the opening of the SU-8 layer that forms the device window (scale bar: 25 μm). The blue inset shows a close-up image on one of the two devices inside the device window. The source-drain pads lie on pads fabricated from the device layer for better contact and surface area. The nanowires are a part of the device layer, laying on the buried oxide, and are 125 nm in width and 75 nm high (scale bar: 5 μm). (c) Electrical characterization of a representative device. The source-drain voltage was swept between −0.4 and 0.15 V, and the gate was kept constant at −0.3 V (black curve), −0.2 V (red curve), −0.1 V (green curve), 0 V (blue curve), and 0.1 V (light blue curve). Inset illustrates how the measurement was made, mimicking the ex vivo experiments as close as possible. (d) Transconductance measurements of five individual devices on the same microneedle FET. Vsd was kept constant on 0.1 V while the gate was swept between (−0.3) V to 0.4 V.
    Microneedle Array Sensor, supplied by Eppendorf AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microneedle+array+sensor/microneedle+array+sensor/pmc09527802-271-1-8
    Average 90 stars, based on 1 article reviews
    microneedle array sensor - by Bioz Stars, 2026-09
    90/100 stars

    Images

    1) Product Images from "The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers"

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers

    Journal: ACS Nano

    doi: 10.1021/acsnano.2c01793

    Fabrication and characterization of the SiNW-FET-based microneedle array sensor. (a) Schematic illustration of the top-down fabrication process. (b) SEM images of the fabricated needles; the needles are 150 μm in width and ca. 250 μm in thickness (scale bar: 125 μm). The green inset shows the opening of the SU-8 layer that forms the device window (scale bar: 25 μm). The blue inset shows a close-up image on one of the two devices inside the device window. The source-drain pads lie on pads fabricated from the device layer for better contact and surface area. The nanowires are a part of the device layer, laying on the buried oxide, and are 125 nm in width and 75 nm high (scale bar: 5 μm). (c) Electrical characterization of a representative device. The source-drain voltage was swept between −0.4 and 0.15 V, and the gate was kept constant at −0.3 V (black curve), −0.2 V (red curve), −0.1 V (green curve), 0 V (blue curve), and 0.1 V (light blue curve). Inset illustrates how the measurement was made, mimicking the ex vivo experiments as close as possible. (d) Transconductance measurements of five individual devices on the same microneedle FET. Vsd was kept constant on 0.1 V while the gate was swept between (−0.3) V to 0.4 V.
    Figure Legend Snippet: Fabrication and characterization of the SiNW-FET-based microneedle array sensor. (a) Schematic illustration of the top-down fabrication process. (b) SEM images of the fabricated needles; the needles are 150 μm in width and ca. 250 μm in thickness (scale bar: 125 μm). The green inset shows the opening of the SU-8 layer that forms the device window (scale bar: 25 μm). The blue inset shows a close-up image on one of the two devices inside the device window. The source-drain pads lie on pads fabricated from the device layer for better contact and surface area. The nanowires are a part of the device layer, laying on the buried oxide, and are 125 nm in width and 75 nm high (scale bar: 5 μm). (c) Electrical characterization of a representative device. The source-drain voltage was swept between −0.4 and 0.15 V, and the gate was kept constant at −0.3 V (black curve), −0.2 V (red curve), −0.1 V (green curve), 0 V (blue curve), and 0.1 V (light blue curve). Inset illustrates how the measurement was made, mimicking the ex vivo experiments as close as possible. (d) Transconductance measurements of five individual devices on the same microneedle FET. Vsd was kept constant on 0.1 V while the gate was swept between (−0.3) V to 0.4 V.

    Techniques Used: Ex Vivo

    Microneedle array dimensions and blood contact. (a) Optical image of comparison in size between common 27G needle for venous blood extraction and the proposed microneedle array sensors. Two types of fabricated microneedles length are shown −400 μm and 1 mm. Scale bar: 5 mm. (b) Schematic illustration of microneedle insertion to the forearm. 1 mm microneedle should reach the blood capillaries in the dermis, while 400 μm needles will not reach as effectively. (c) Optical images showing the microneedle before (top) and after (bottom) a blood droplet was placed on the microneedle. Orange inset shows blood is clearly able to enter the SU-8 window. (d) Optical image showing the microneedle after insertion to the skin. (e) Schematic illustration of a different possible location for protein detection in the blood. The microneedle array can be used in the finger without or with prior pricking.
    Figure Legend Snippet: Microneedle array dimensions and blood contact. (a) Optical image of comparison in size between common 27G needle for venous blood extraction and the proposed microneedle array sensors. Two types of fabricated microneedles length are shown −400 μm and 1 mm. Scale bar: 5 mm. (b) Schematic illustration of microneedle insertion to the forearm. 1 mm microneedle should reach the blood capillaries in the dermis, while 400 μm needles will not reach as effectively. (c) Optical images showing the microneedle before (top) and after (bottom) a blood droplet was placed on the microneedle. Orange inset shows blood is clearly able to enter the SU-8 window. (d) Optical image showing the microneedle after insertion to the skin. (e) Schematic illustration of a different possible location for protein detection in the blood. The microneedle array can be used in the finger without or with prior pricking.

    Techniques Used: Comparison, Extraction

    Skin insertion and contact with blood vessels. (a) Images of the insertion process of the microneedle array sensors into the forearm. (b) Images showing several insertion experiments of 1 mm microneedle array (left) and 0.4 mm microneedle array (right) to the forearm. (c) Summarized results of blood drawing from insertion experiments of 1 mm microneedle array (red) and 0.4 mm microneedle array (green) to the forearm. (d) Statistical distribution of blood drawing success percentage from 50 insertion experiments of 1 mm microneedle array (black) and 0.4 mm microneedle array (red) to the forearm.
    Figure Legend Snippet: Skin insertion and contact with blood vessels. (a) Images of the insertion process of the microneedle array sensors into the forearm. (b) Images showing several insertion experiments of 1 mm microneedle array (left) and 0.4 mm microneedle array (right) to the forearm. (c) Summarized results of blood drawing from insertion experiments of 1 mm microneedle array (red) and 0.4 mm microneedle array (green) to the forearm. (d) Statistical distribution of blood drawing success percentage from 50 insertion experiments of 1 mm microneedle array (black) and 0.4 mm microneedle array (red) to the forearm.

    Techniques Used:

    In vivo results of different measurements using the microneedle array. (a) Stabilization curves of PSA association at 10 pM (red curve) and 100 pM (blue curve) spiked-PBS solutions. The results indicate that the sensor requires approximately 60 s to achieve a differentiable signal. (b) One cycle close-up view taken once dissociation stabilization is achieved for PSA-spiked PBS buffer. (c) One cycle close-up view taken once dissociation stabilization is achieved for PSA-spiked serum. (d) Normalized response linear curves derived from (a) and (b). The dissociation phase was conducted in 5% EG in 100 μM phosphate buffer solution. Normalized reaction is in comparison to nonspiked buffer or serum, respectively. Pink data relates to nonspecific normalized response to 22 ng/mL cTnI and 21 ng/mL GFP. (e) In vivo intradermal capillary PSA concentrations were measured in four subjects using the microneedle array (green bars) compared to ELISA measurements of PSA concentration in venous blood (blue dots). (f) Multiplex experiment results of normalized response to PSA-spiked buffer from a device modified with PSA-specific antibody (αPSA, black curve) and a device modified with cTnI-specific antibody (αcTnI, red curve). (g) Multiplex experiment results of normalized response to cTnI-spiked buffer from a device modified with PSA-specific antibody (αPSA, black curve) and a device modified with cTnI-specific antibody (αcTnI, red curve). (i) Top: Deviation measurements performed on a single device via multiple entries to (100 pM spiked serum solution). Bottom: Variance measurements were performed between different devices via normalized response against a 100 pM spiked serum.
    Figure Legend Snippet: In vivo results of different measurements using the microneedle array. (a) Stabilization curves of PSA association at 10 pM (red curve) and 100 pM (blue curve) spiked-PBS solutions. The results indicate that the sensor requires approximately 60 s to achieve a differentiable signal. (b) One cycle close-up view taken once dissociation stabilization is achieved for PSA-spiked PBS buffer. (c) One cycle close-up view taken once dissociation stabilization is achieved for PSA-spiked serum. (d) Normalized response linear curves derived from (a) and (b). The dissociation phase was conducted in 5% EG in 100 μM phosphate buffer solution. Normalized reaction is in comparison to nonspiked buffer or serum, respectively. Pink data relates to nonspecific normalized response to 22 ng/mL cTnI and 21 ng/mL GFP. (e) In vivo intradermal capillary PSA concentrations were measured in four subjects using the microneedle array (green bars) compared to ELISA measurements of PSA concentration in venous blood (blue dots). (f) Multiplex experiment results of normalized response to PSA-spiked buffer from a device modified with PSA-specific antibody (αPSA, black curve) and a device modified with cTnI-specific antibody (αcTnI, red curve). (g) Multiplex experiment results of normalized response to cTnI-spiked buffer from a device modified with PSA-specific antibody (αPSA, black curve) and a device modified with cTnI-specific antibody (αcTnI, red curve). (i) Top: Deviation measurements performed on a single device via multiple entries to (100 pM spiked serum solution). Bottom: Variance measurements were performed between different devices via normalized response against a 100 pM spiked serum.

    Techniques Used: In Vivo, Derivative Assay, Comparison, Enzyme-linked Immunosorbent Assay, Concentration Assay, Multiplex Assay, Modification

    Laboratory-scale 3D-printed mount. (a) Illustration of the mount that enables the microneedle-based sensor operation. The mount chip is held for the user to prick his finger using the microneedles, followed by capping of the mount and consecutive washing in the appropriate buffer solution. (b) Optical images show the 3D-printed mount and the laboratory-scale system. (c) Optical image illustrating finger pricking using the 3D-printed mount.
    Figure Legend Snippet: Laboratory-scale 3D-printed mount. (a) Illustration of the mount that enables the microneedle-based sensor operation. The mount chip is held for the user to prick his finger using the microneedles, followed by capping of the mount and consecutive washing in the appropriate buffer solution. (b) Optical images show the 3D-printed mount and the laboratory-scale system. (c) Optical image illustrating finger pricking using the 3D-printed mount.

    Techniques Used:

    Related Articles

    Ex Vivo:

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers
    Article Snippet: was constantly applied using 0.2 V. The in vitro measurements took place either in 1× phosphate buffer saline (PBS) or as-received bovine serum. .. The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min). .. The desorption took place in a 5% EG solution in sensing buffer (phosphate buffer diluted by a factor of 100) using 2 mL solutions as well, until stab

    Comparison:

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers
    Article Snippet: was constantly applied using 0.2 V. The in vitro measurements took place either in 1× phosphate buffer saline (PBS) or as-received bovine serum. .. The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min). .. The desorption took place in a 5% EG solution in sensing buffer (phosphate buffer diluted by a factor of 100) using 2 mL solutions as well, until stab

    Extraction:

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers
    Article Snippet: was constantly applied using 0.2 V. The in vitro measurements took place either in 1× phosphate buffer saline (PBS) or as-received bovine serum. .. The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min). .. The desorption took place in a 5% EG solution in sensing buffer (phosphate buffer diluted by a factor of 100) using 2 mL solutions as well, until stab

    In Vivo:

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers
    Article Snippet: was constantly applied using 0.2 V. The in vitro measurements took place either in 1× phosphate buffer saline (PBS) or as-received bovine serum. .. The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min). .. The desorption took place in a 5% EG solution in sensing buffer (phosphate buffer diluted by a factor of 100) using 2 mL solutions as well, until stab

    Derivative Assay:

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers
    Article Snippet: was constantly applied using 0.2 V. The in vitro measurements took place either in 1× phosphate buffer saline (PBS) or as-received bovine serum. .. The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min). .. The desorption took place in a 5% EG solution in sensing buffer (phosphate buffer diluted by a factor of 100) using 2 mL solutions as well, until stab

    Enzyme-linked Immunosorbent Assay:

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers
    Article Snippet: was constantly applied using 0.2 V. The in vitro measurements took place either in 1× phosphate buffer saline (PBS) or as-received bovine serum. .. The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min). .. The desorption took place in a 5% EG solution in sensing buffer (phosphate buffer diluted by a factor of 100) using 2 mL solutions as well, until stab

    Concentration Assay:

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers
    Article Snippet: was constantly applied using 0.2 V. The in vitro measurements took place either in 1× phosphate buffer saline (PBS) or as-received bovine serum. .. The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min). .. The desorption took place in a 5% EG solution in sensing buffer (phosphate buffer diluted by a factor of 100) using 2 mL solutions as well, until stab

    Multiplex Assay:

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers
    Article Snippet: was constantly applied using 0.2 V. The in vitro measurements took place either in 1× phosphate buffer saline (PBS) or as-received bovine serum. .. The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min). .. The desorption took place in a 5% EG solution in sensing buffer (phosphate buffer diluted by a factor of 100) using 2 mL solutions as well, until stab

    Modification:

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers
    Article Snippet: was constantly applied using 0.2 V. The in vitro measurements took place either in 1× phosphate buffer saline (PBS) or as-received bovine serum. .. The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min). .. The desorption took place in a 5% EG solution in sensing buffer (phosphate buffer diluted by a factor of 100) using 2 mL solutions as well, until stab



    Similar Products

    90
    Eppendorf AG microneedle array sensor
    Fabrication and characterization of the SiNW-FET-based <t>microneedle</t> array sensor. (a) Schematic illustration of the top-down fabrication process. (b) SEM images of the fabricated needles; the needles are 150 μm in width and ca. 250 μm in thickness (scale bar: 125 μm). The green inset shows the opening of the SU-8 layer that forms the device window (scale bar: 25 μm). The blue inset shows a close-up image on one of the two devices inside the device window. The source-drain pads lie on pads fabricated from the device layer for better contact and surface area. The nanowires are a part of the device layer, laying on the buried oxide, and are 125 nm in width and 75 nm high (scale bar: 5 μm). (c) Electrical characterization of a representative device. The source-drain voltage was swept between −0.4 and 0.15 V, and the gate was kept constant at −0.3 V (black curve), −0.2 V (red curve), −0.1 V (green curve), 0 V (blue curve), and 0.1 V (light blue curve). Inset illustrates how the measurement was made, mimicking the ex vivo experiments as close as possible. (d) Transconductance measurements of five individual devices on the same microneedle FET. Vsd was kept constant on 0.1 V while the gate was swept between (−0.3) V to 0.4 V.
    Microneedle Array Sensor, supplied by Eppendorf AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microneedle+array+sensor/microneedle+array+sensor/pmc09527802-271-1-8
    Average 90 stars, based on 1 article reviews
    microneedle array sensor - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    Fabrication and characterization of the SiNW-FET-based microneedle array sensor. (a) Schematic illustration of the top-down fabrication process. (b) SEM images of the fabricated needles; the needles are 150 μm in width and ca. 250 μm in thickness (scale bar: 125 μm). The green inset shows the opening of the SU-8 layer that forms the device window (scale bar: 25 μm). The blue inset shows a close-up image on one of the two devices inside the device window. The source-drain pads lie on pads fabricated from the device layer for better contact and surface area. The nanowires are a part of the device layer, laying on the buried oxide, and are 125 nm in width and 75 nm high (scale bar: 5 μm). (c) Electrical characterization of a representative device. The source-drain voltage was swept between −0.4 and 0.15 V, and the gate was kept constant at −0.3 V (black curve), −0.2 V (red curve), −0.1 V (green curve), 0 V (blue curve), and 0.1 V (light blue curve). Inset illustrates how the measurement was made, mimicking the ex vivo experiments as close as possible. (d) Transconductance measurements of five individual devices on the same microneedle FET. Vsd was kept constant on 0.1 V while the gate was swept between (−0.3) V to 0.4 V.

    Journal: ACS Nano

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers

    doi: 10.1021/acsnano.2c01793

    Figure Lengend Snippet: Fabrication and characterization of the SiNW-FET-based microneedle array sensor. (a) Schematic illustration of the top-down fabrication process. (b) SEM images of the fabricated needles; the needles are 150 μm in width and ca. 250 μm in thickness (scale bar: 125 μm). The green inset shows the opening of the SU-8 layer that forms the device window (scale bar: 25 μm). The blue inset shows a close-up image on one of the two devices inside the device window. The source-drain pads lie on pads fabricated from the device layer for better contact and surface area. The nanowires are a part of the device layer, laying on the buried oxide, and are 125 nm in width and 75 nm high (scale bar: 5 μm). (c) Electrical characterization of a representative device. The source-drain voltage was swept between −0.4 and 0.15 V, and the gate was kept constant at −0.3 V (black curve), −0.2 V (red curve), −0.1 V (green curve), 0 V (blue curve), and 0.1 V (light blue curve). Inset illustrates how the measurement was made, mimicking the ex vivo experiments as close as possible. (d) Transconductance measurements of five individual devices on the same microneedle FET. Vsd was kept constant on 0.1 V while the gate was swept between (−0.3) V to 0.4 V.

    Article Snippet: The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min).

    Techniques: Ex Vivo

    Microneedle array dimensions and blood contact. (a) Optical image of comparison in size between common 27G needle for venous blood extraction and the proposed microneedle array sensors. Two types of fabricated microneedles length are shown −400 μm and 1 mm. Scale bar: 5 mm. (b) Schematic illustration of microneedle insertion to the forearm. 1 mm microneedle should reach the blood capillaries in the dermis, while 400 μm needles will not reach as effectively. (c) Optical images showing the microneedle before (top) and after (bottom) a blood droplet was placed on the microneedle. Orange inset shows blood is clearly able to enter the SU-8 window. (d) Optical image showing the microneedle after insertion to the skin. (e) Schematic illustration of a different possible location for protein detection in the blood. The microneedle array can be used in the finger without or with prior pricking.

    Journal: ACS Nano

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers

    doi: 10.1021/acsnano.2c01793

    Figure Lengend Snippet: Microneedle array dimensions and blood contact. (a) Optical image of comparison in size between common 27G needle for venous blood extraction and the proposed microneedle array sensors. Two types of fabricated microneedles length are shown −400 μm and 1 mm. Scale bar: 5 mm. (b) Schematic illustration of microneedle insertion to the forearm. 1 mm microneedle should reach the blood capillaries in the dermis, while 400 μm needles will not reach as effectively. (c) Optical images showing the microneedle before (top) and after (bottom) a blood droplet was placed on the microneedle. Orange inset shows blood is clearly able to enter the SU-8 window. (d) Optical image showing the microneedle after insertion to the skin. (e) Schematic illustration of a different possible location for protein detection in the blood. The microneedle array can be used in the finger without or with prior pricking.

    Article Snippet: The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min).

    Techniques: Comparison, Extraction

    Skin insertion and contact with blood vessels. (a) Images of the insertion process of the microneedle array sensors into the forearm. (b) Images showing several insertion experiments of 1 mm microneedle array (left) and 0.4 mm microneedle array (right) to the forearm. (c) Summarized results of blood drawing from insertion experiments of 1 mm microneedle array (red) and 0.4 mm microneedle array (green) to the forearm. (d) Statistical distribution of blood drawing success percentage from 50 insertion experiments of 1 mm microneedle array (black) and 0.4 mm microneedle array (red) to the forearm.

    Journal: ACS Nano

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers

    doi: 10.1021/acsnano.2c01793

    Figure Lengend Snippet: Skin insertion and contact with blood vessels. (a) Images of the insertion process of the microneedle array sensors into the forearm. (b) Images showing several insertion experiments of 1 mm microneedle array (left) and 0.4 mm microneedle array (right) to the forearm. (c) Summarized results of blood drawing from insertion experiments of 1 mm microneedle array (red) and 0.4 mm microneedle array (green) to the forearm. (d) Statistical distribution of blood drawing success percentage from 50 insertion experiments of 1 mm microneedle array (black) and 0.4 mm microneedle array (red) to the forearm.

    Article Snippet: The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min).

    Techniques:

    In vivo results of different measurements using the microneedle array. (a) Stabilization curves of PSA association at 10 pM (red curve) and 100 pM (blue curve) spiked-PBS solutions. The results indicate that the sensor requires approximately 60 s to achieve a differentiable signal. (b) One cycle close-up view taken once dissociation stabilization is achieved for PSA-spiked PBS buffer. (c) One cycle close-up view taken once dissociation stabilization is achieved for PSA-spiked serum. (d) Normalized response linear curves derived from (a) and (b). The dissociation phase was conducted in 5% EG in 100 μM phosphate buffer solution. Normalized reaction is in comparison to nonspiked buffer or serum, respectively. Pink data relates to nonspecific normalized response to 22 ng/mL cTnI and 21 ng/mL GFP. (e) In vivo intradermal capillary PSA concentrations were measured in four subjects using the microneedle array (green bars) compared to ELISA measurements of PSA concentration in venous blood (blue dots). (f) Multiplex experiment results of normalized response to PSA-spiked buffer from a device modified with PSA-specific antibody (αPSA, black curve) and a device modified with cTnI-specific antibody (αcTnI, red curve). (g) Multiplex experiment results of normalized response to cTnI-spiked buffer from a device modified with PSA-specific antibody (αPSA, black curve) and a device modified with cTnI-specific antibody (αcTnI, red curve). (i) Top: Deviation measurements performed on a single device via multiple entries to (100 pM spiked serum solution). Bottom: Variance measurements were performed between different devices via normalized response against a 100 pM spiked serum.

    Journal: ACS Nano

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers

    doi: 10.1021/acsnano.2c01793

    Figure Lengend Snippet: In vivo results of different measurements using the microneedle array. (a) Stabilization curves of PSA association at 10 pM (red curve) and 100 pM (blue curve) spiked-PBS solutions. The results indicate that the sensor requires approximately 60 s to achieve a differentiable signal. (b) One cycle close-up view taken once dissociation stabilization is achieved for PSA-spiked PBS buffer. (c) One cycle close-up view taken once dissociation stabilization is achieved for PSA-spiked serum. (d) Normalized response linear curves derived from (a) and (b). The dissociation phase was conducted in 5% EG in 100 μM phosphate buffer solution. Normalized reaction is in comparison to nonspiked buffer or serum, respectively. Pink data relates to nonspecific normalized response to 22 ng/mL cTnI and 21 ng/mL GFP. (e) In vivo intradermal capillary PSA concentrations were measured in four subjects using the microneedle array (green bars) compared to ELISA measurements of PSA concentration in venous blood (blue dots). (f) Multiplex experiment results of normalized response to PSA-spiked buffer from a device modified with PSA-specific antibody (αPSA, black curve) and a device modified with cTnI-specific antibody (αcTnI, red curve). (g) Multiplex experiment results of normalized response to cTnI-spiked buffer from a device modified with PSA-specific antibody (αPSA, black curve) and a device modified with cTnI-specific antibody (αcTnI, red curve). (i) Top: Deviation measurements performed on a single device via multiple entries to (100 pM spiked serum solution). Bottom: Variance measurements were performed between different devices via normalized response against a 100 pM spiked serum.

    Article Snippet: The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min).

    Techniques: In Vivo, Derivative Assay, Comparison, Enzyme-linked Immunosorbent Assay, Concentration Assay, Multiplex Assay, Modification

    Laboratory-scale 3D-printed mount. (a) Illustration of the mount that enables the microneedle-based sensor operation. The mount chip is held for the user to prick his finger using the microneedles, followed by capping of the mount and consecutive washing in the appropriate buffer solution. (b) Optical images show the 3D-printed mount and the laboratory-scale system. (c) Optical image illustrating finger pricking using the 3D-printed mount.

    Journal: ACS Nano

    Article Title: The “Bloodless” Blood Test: Intradermal Prick Nanoelectronics for the Blood Extraction-Free Multiplex Detection of Protein Biomarkers

    doi: 10.1021/acsnano.2c01793

    Figure Lengend Snippet: Laboratory-scale 3D-printed mount. (a) Illustration of the mount that enables the microneedle-based sensor operation. The mount chip is held for the user to prick his finger using the microneedles, followed by capping of the mount and consecutive washing in the appropriate buffer solution. (b) Optical images show the 3D-printed mount and the laboratory-scale system. (c) Optical image illustrating finger pricking using the 3D-printed mount.

    Article Snippet: The microneedle array sensor was placed inside an Eppendorf containing a 2 mL solution of either unspiked (“clean”) or PSA-spiked solutions in different concentrations until stabilization (approximately 8 min).

    Techniques: